Product

ehb SMARTmodul 04 RPM Modul

ehb SMARTmodul 04 RPM Modul

ehb5000x

The ehb SMARTmodul 04 delivers a multitude of functions for monitoring and controlling applications via CAN bus (SAE J1939).

Analogue, digital and CAN bus signals are reliably interconnected and evaluated
Simple networking of a multitude of sensors, actuators and units.

Inputs and outputs can be controlled via CAN bus
Control tasks are easily achieved via the connected HMI without programming efforts at the controller

Individually programmable according to customer specification
The standard components can be enhanced by adaptations to the requirement of specific applications.

UV-resistant, rugged PA6 housing for screwed installation.
Connection via standard plug connectors.

Fast installation and retrofit. Dependable functioning in industrial environments.

No direct access to the sensors installed at the motor
The engine warranty is not affected.

Diverse basic variants
Individual requirements can be inexpensively configured

Speed module:

  • Speed adjustment with simple switches and push-butt
  • The programmable working speed can be approached by ramp.
  • Output for analogue speed indication.

Display module:

  • Supports 12V and 24V standard instruments.
  • Engine oil pressure, engine oil and coolant temperature, fuel gauge, speed indicator and much more.
  • An engine change does not require the display panel to be replaced.

I/O module:

  • Configurable for up to four digital inputs and/or outputs.

Sensor module:

  • Transmission of current measured values from four analogue inputs to the CAN bus
show full product desription

Application

  • Construction machinery Construction machinery
  • Agricultural engineering (agricultural machines) Agricultural engineering (agricultural machines)
  • Maritime applications Maritime applications
  • Municipal utility vehicles Municipal utility vehicles
  • Plant engineering Plant engineering

Electrical Data

Voltage range

8 – 32V (typ. 12 – 24V)

Interference

14 – 28V (6Vss, 50Hz on UB)

Voltage peaks

200V (2ms on UB)

Power consumption

< 5 – 200mA (in UB 8 – 24V)

Operating temperature

-40°C to +105°C

Storage temperature

-55°C to +105°C

Pin assignment

PIN 3: UPM+
PIN 7: UPM-
PIN 2: Working speed
PIN 6: Frequency output, revolution counter
PIN 5: CAN-High
PIN 1: CAN-Low
PIN 8: KL. 15
PIN 4: KL. 31

CAN bus interface

CAN 2.0B, 250kBit/s, SAE J1939

Visualisation

Mechanical Data

Installed dimension (W x H x D)

61 x 60 x 35,4mm
95,5 x 71 x 35,4mm (including mounting and plug)

Housing material

PA 6.6

Weight

98 g

Installation

2 screws with mounting brackets

Degree of protection

P 53

Connection

AMP/Tyco positive lock 8-pole

Testing standards

Humidity

DIN EN 60068-2-3

Vibration

DIN EN 60068-2-6

Impact

DIN EN 60068-2-27

CE marking

according to Directive 2014/30/EU

Technical Drawings

To the top of the page Print page