HC960

FAQ

Question

Solenoid valve output (feed) starts pulsing

Answer

Output is overloaded. To prevent damage to the transistor, it starts to pulse through the overload protection.


"TH" flashes alternately with the operating hours during operation

The HC960 is expecting a speed. Check whether the speed signal is present.